Technical Parameters:

Model: UT25/UT25C

Display screen£º1.44 Inch color LCD display

Voltage measurement range:4-24.000V

Voltage measurement resolution:0.001V

Current measurement range: 0-5.0000A

Current measurement resolution: 0.0001A

Capacity accumulation range: 0-99999mAh

Voltage measurement accuracy:¡À£¨0.5¡ë+2digits£©

Energy accumulation range:0-99999mWh? ?

Current measurement accuracy:¡À£¨1¡ë +4 digits£©

Load impedance range: 0.8¦¸-9999.9¦¸ ??

Time measurement range:0-99h59min59s

Temperature range:-10¡æ~100¡æ/0¨H~200¨H

Temperature measurement error:¡À 3¡æ/ ¡À 6¨H

Screen brightness setting: Levels 0-5 ?

Delay off the screen time£º0-9minutes

Voltage graphing range: 4-24.00V ?

Current graphing range:0-5.000A

Product weight:23.74g(UT25C)/19.26g (UT25)

Refresh rate: 2Hz

(No packaging)£»54.56g(UT25C)/50.08g (UT25)( With packaging)?

Dimensions£º71.2mmx30.5mmx12.4mm

Quick charge recognition mode£ºQC2.0¡¢QC3.0¡¢APPLE 2.4A/2.1A/ 1A/0.5A¡¢Android DCP¡¢SAMSUNG

?

?

Function Interfaces

?

The Core Function:

PC Bluetooth Communication Android Phone APP Control ?Quick Charge Recognition Data Record and Store Capacity/Energy Detection Differential Voltage Method Measurement Data Connection Cable Impedance Voltage/Current/Power Detection Load connecting detection function (screen auto off, plug the load, screen auto lighting)

Device Layout

?

A£ºMicro USB Port?

B£ºMultifunction buttons (4)

C£ºBluetooth Switch

D£ºUSB A Female Port

E£ºUSB A Male Port?

F£ºType-C Input Port (Only VBUS¡¢GND¡¢CC1¡¢CC2 four wires)

G£º1.44 Inch Color Screen

H£ºType-C Output Port (Only VBUS¡¢GND¡¢CC1¡¢CC2 four wires)

Interface Prompt Representing Functions:

1£ºPress and hold the key to rotate the Screen Left

2£ºPress the key to close the screen

3£ºPress the key to open the help interface?

4£º Press and hold the key to rotate the screen right?

5£ºPress PREV to previous page

6£ºPress Next to next page

Operating Instructions

When the unit is first powered on the welcome screen is displayed followed shortly by the main interface screen.

Hidden interface: Pressing any button whilst powering on the module will display three options. Option 1 selects the Chinese Interface and option 2 selects the English interface.?

The third option is to reset£¨after reset, system setting data was restored to the factory setting, all the stored data was not reset£©.Release the button at the desired selection.

Pressing and holding the button after stepping to the third option will exit the hidden interface.

Interface 1: Main Measurment Interface.( As shown below) ?

7£ºVoltage Measurement ?

8£ºCurrent Measurement

9£ºAccumulated Capacity

10£ºAccumulated Energy

11£ºTemperature Measurement 12£ºNumber of the Data Group in use

13£ºLoad Equivalent Impedance

14£ºPower Measurement

?Press the ¡® ? ¡¯ button to enter the interface as shown above:?

Press and hold the ¡®NEXT¡¯ button to switch Data Group. The USB tester can provide a total of 10 groups of data to save and view. These are numbered 0-9.

?With Data Groups 1-9 selected the current mAh and mWh are saved after power off. They will continue accumulating the next time the tester is powered on. When the data group selected is 0 then the current value of mAh and mWh will be temporarily saved at power off. When the device is next powered on these values will be recalled and will begin flashing. When the accumulated mAh exceeds 1 mAh, the previous data will be cleared and accumulation will restart.

With a Data Group selected, press and hold the ¡®PREV¡¯ button to clear the mAh and mWh.

(As shown)

Press ¡®NEXT¡¯ to switch to the Quick Charge Recognition Interface. ?

Interface 2: Quick Charge Recognition Interface

15£ºD +: (DP) data positive signal level.

16£ºD-: (DM), data negative signal level.

17£ºMode display

The? product ? will automatically identify a device with a supported fast charging mode. At this time the device supports the QC2.0¡¢QC3.0¡¢APPLE? 2.4A/2.1A/ 1A/0.5A¡¢Android DCP¡¢SAMSUNG.(Note: This quick charge agreement recognition model is??for reference only, because cell phone updated quickly, it can't be absolutely accurate identification£© ?Press ¡®NEXT¡¯ to switch to the Charging Recording Interface.

Interface 3: Charging Recording Interface

18£ºAccumulated Capacity

19£ºAccumulated Energy

20£ºTime display£ºThe total accumulated recording time.

21£ºCapacity/Energy statistics trigger current

22£ºREC£ºrecording status indicator. ¡®REC¡¯

displayed in red indicates that recording is stopped. ¡®REC¡¯ displayed in green indicates that recording is in progress.

After power on, when the current flowing is greater than the Low Current trigger value. The system automatically begins to record the accumulated capacity, energy, and time elapsed. The ¡®REC¡¯ indicator will change from red to green.?

To set the Current trigger value, press and hold the "Next" button to highlight the value then press the ¡®PREV¡¯ button to adjust the value as required. The value can be set anywhere between 0.01A- and 0.30A. (10mA to 300mA).

Press "Next" button to switch to the Data Connection Cable impedance Measurement Interface.

Interface 4: Data Connection Cable Impedance Measurement Interface.

The Tester can use differential voltage method to measure the resistance of a data connection cable

23£ºUSB Tester directly connected to the power supply with Voltage and Current values displayed

24£ºUSB Tester connected via a data connection cable with Voltage and Current values displayed.

25£ºR: Data Connection Cable resistance.?

Measurement procedure:

First, connect the USB Tester directly to the power supply and adjust the appropriate load current (recommended value 1A) . Press and hold the ¡®NEXT¡¯ button to begin recording data. The indicator prompt will stop flashing .?

Second, unplug the USB Tester and then reconnect it to the power supply via the Micro USB/Type-C IN data connection cable and adjust the load current to the same value as in the first step. Press and hold the ¡®NEXT¡¯ button to begin recording data. The indicator prompt stops flashing and the Data Connection Cable resistance measurement test is completed and the value displayed. ?

Note: If during the second step the screen turns black, this indicates that the voltage difference is too high and the tester will enter the 4V power-down state. The load current needs be reduced. Then re-start the measurement from the first step. After the Data Connection Cable resistance test is completed, the Tester needs to be powered off and then on again to resume measurement. ?

Press the ¡®NEXT¡¯ button to switch to the Measurement Graphing Interface.?

?

Interface 5: Measurement Graphing Interface

? ? ? ? ?

This interface displays the voltage measurement over time in the 4-24V range and will automatically adjust the displayed range in real time to account for voltage fluctuations. And the current measurement over time in the 0-5.000A range and will automatically adjust the display range in real time to account for current fluctuations.

Press and hold ¡°NEXT¡± to switch to D+D- graphing, as picture

This interface displays the D+ /D- voltage measurement over time in the 0-3.3V range and will automatically adjust the displayed range in real time to account for D+/D- voltage fluctuations.

?

Press the ¡®NEXT¡¯ button to switch to the system parameter setting interface.

Interface 6: System Parameter Setting Interface?

26£ºAuto screen off time

27£ºScreen brightness

28£ºTemperature display C /F

29£ºTheme background color?

30£ºTheme foreground color

Press and hold the "Next" button

to enter into setting state, press ¡°NEXT¡± button to step through the options of auto screen off time, brightness level, temperature display units, theme background color and theme foreground color. Stop on the value you wish to change then press the "PREV" button to change the setting.?

For auto screen off time setting press ¡®PREV¡¯ to repeatedly step though the 10 options from 0 to 9 minutes. Default time is 1 minutes.?

?For the screen brightness setting, press ¡®PREV¡¯ to repeatedly step though the 6 options from 0 to 5 where 0 is the lowest brightness level and 5 is the highest. Default brightness is 4.?

For the temperature display units, pressing the ¡®Next¡¯ button toggles the setting between C and F. default temperature unite is C.?

For theme background color, press ¡®PREV¡¯ to repeatedly step though the 7 options from 0 to 6 where the color sequence is red, green, blue, yellow, light blue, pink, white and black. Default color is 2, blue.?

For theme foreground color, press ¡®PREV¡¯ to repeatedly step though the 7 options from 0 to 6

where the color sequence is red, green, blue, yellow, light blue, pink, white and black. Default ?color is 6, white.

?At any setting state, press and hold the ¡®Next¡¯ button to exit the settings menu.

trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancyservice@diytech.cc

Technical Parameters:

Model: UT25/UT25C

Display screen£º1.44 Inch color LCD display

Voltage measurement range:4-24.000V

Voltage measurement resolution:0.001V

Current measurement range: 0-5.0000A

Current measurement resolution: 0.0001A

Capacity accumulation range: 0-99999mAh

Voltage measurement accuracy:¡À£¨0.5¡ë+2digits£©

Energy accumulation range:0-99999mWh? ?

Current measurement accuracy:¡À£¨1¡ë +4 digits£©

Load impedance range: 0.8¦¸-9999.9¦¸ ??

Time measurement range:0-99h59min59s

Temperature range:-10¡æ~100¡æ/0¨H~200¨H

Temperature measurement error:¡À 3¡æ/ ¡À 6¨H

Screen brightness setting: Levels 0-5 ?

Delay off the screen time£º0-9minutes

Voltage graphing range: 4-24.00V ?

Current graphing range:0-5.000A

Product weight:23.74g(UT25C)/19.26g (UT25)

Refresh rate: 2Hz

(No packaging)£»54.56g(UT25C)/50.08g (UT25)( With packaging)?

Dimensions£º71.2mmx30.5mmx12.4mm

Quick charge recognition mode£ºQC2.0¡¢QC3.0¡¢APPLE 2.4A/2.1A/ 1A/0.5A¡¢Android DCP¡¢SAMSUNG

?

?

Function Interfaces

?

The Core Function:

PC Bluetooth Communication Android Phone APP Control ?Quick Charge Recognition Data Record and Store Capacity/Energy Detection Differential Voltage Method Measurement Data Connection Cable Impedance Voltage/Current/Power Detection Load connecting detection function (screen auto off, plug the load, screen auto lighting)

Device Layout

?

A£ºMicro USB Port?

B£ºMultifunction buttons (4)

C£ºBluetooth Switch

D£ºUSB A Female Port

E£ºUSB A Male Port?

F£ºType-C Input Port (Only VBUS¡¢GND¡¢CC1¡¢CC2 four wires)

G£º1.44 Inch Color Screen

H£ºType-C Output Port (Only VBUS¡¢GND¡¢CC1¡¢CC2 four wires)

Interface Prompt Representing Functions:

1£ºPress and hold the key to rotate the Screen Left

2£ºPress the key to close the screen

3£ºPress the key to open the help interface?

4£º Press and hold the key to rotate the screen right?

5£ºPress PREV to previous page

6£ºPress Next to next page

Operating Instructions

When the unit is first powered on the welcome screen is displayed followed shortly by the main interface screen.

Hidden interface: Pressing any button whilst powering on the module will display three options. Option 1 selects the Chinese Interface and option 2 selects the English interface.?

The third option is to reset£¨after reset, system setting data was restored to the factory setting, all the stored data was not reset£©.Release the button at the desired selection.

Pressing and holding the button after stepping to the third option will exit the hidden interface.

Interface 1: Main Measurment Interface.( As shown below) ?

7£ºVoltage Measurement ?

8£ºCurrent Measurement

9£ºAccumulated Capacity

10£ºAccumulated Energy

11£ºTemperature Measurement 12£ºNumber of the Data Group in use

13£ºLoad Equivalent Impedance

14£ºPower Measurement

?Press the ¡® ? ¡¯ button to enter the interface as shown above:?

Press and hold the ¡®NEXT¡¯ button to switch Data Group. The USB tester can provide a total of 10 groups of data to save and view. These are numbered 0-9.

?With Data Groups 1-9 selected the current mAh and mWh are saved after power off. They will continue accumulating the next time the tester is powered on. When the data group selected is 0 then the current value of mAh and mWh will be temporarily saved at power off. When the device is next powered on these values will be recalled and will begin flashing. When the accumulated mAh exceeds 1 mAh, the previous data will be cleared and accumulation will restart.

With a Data Group selected, press and hold the ¡®PREV¡¯ button to clear the mAh and mWh.

(As shown)

Press ¡®NEXT¡¯ to switch to the Quick Charge Recognition Interface. ?

Interface 2: Quick Charge Recognition Interface

15£ºD +: (DP) data positive signal level.

16£ºD-: (DM), data negative signal level.

17£ºMode display

The? product ? will automatically identify a device with a supported fast charging mode. At this time the device supports the QC2.0¡¢QC3.0¡¢APPLE? 2.4A/2.1A/ 1A/0.5A¡¢Android DCP¡¢SAMSUNG.(Note: This quick charge agreement recognition model is??for reference only, because cell phone updated quickly, it can't be absolutely accurate identification£© ?Press ¡®NEXT¡¯ to switch to the Charging Recording Interface.

Interface 3: Charging Recording Interface

18£ºAccumulated Capacity

19£ºAccumulated Energy

20£ºTime display£ºThe total accumulated recording time.

21£ºCapacity/Energy statistics trigger current

22£ºREC£ºrecording status indicator. ¡®REC¡¯

displayed in red indicates that recording is stopped. ¡®REC¡¯ displayed in green indicates that recording is in progress.

After power on, when the current flowing is greater than the Low Current trigger value. The system automatically begins to record the accumulated capacity, energy, and time elapsed. The ¡®REC¡¯ indicator will change from red to green.?

To set the Current trigger value, press and hold the "Next" button to highlight the value then press the ¡®PREV¡¯ button to adjust the value as required. The value can be set anywhere between 0.01A- and 0.30A. (10mA to 300mA).

Press "Next" button to switch to the Data Connection Cable impedance Measurement Interface.

Interface 4: Data Connection Cable Impedance Measurement Interface.

The Tester can use differential voltage method to measure the resistance of a data connection cable

23£ºUSB Tester directly connected to the power supply with Voltage and Current values displayed

24£ºUSB Tester connected via a data connection cable with Voltage and Current values displayed.

25£ºR: Data Connection Cable resistance.?

Measurement procedure:

First, connect the USB Tester directly to the power supply and adjust the appropriate load current (recommended value 1A) . Press and hold the ¡®NEXT¡¯ button to begin recording data. The indicator prompt will stop flashing .?

Second, unplug the USB Tester and then reconnect it to the power supply via the Micro USB/Type-C IN data connection cable and adjust the load current to the same value as in the first step. Press and hold the ¡®NEXT¡¯ button to begin recording data. The indicator prompt stops flashing and the Data Connection Cable resistance measurement test is completed and the value displayed. ?

Note: If during the second step the screen turns black, this indicates that the voltage difference is too high and the tester will enter the 4V power-down state. The load current needs be reduced. Then re-start the measurement from the first step. After the Data Connection Cable resistance test is completed, the Tester needs to be powered off and then on again to resume measurement. ?

Press the ¡®NEXT¡¯ button to switch to the Measurement Graphing Interface.?

?

Interface 5: Measurement Graphing Interface

? ? ? ? ?

This interface displays the voltage measurement over time in the 4-24V range and will automatically adjust the displayed range in real time to account for voltage fluctuations. And the current measurement over time in the 0-5.000A range and will automatically adjust the display range in real time to account for current fluctuations.

Press and hold ¡°NEXT¡± to switch to D+D- graphing, as picture

This interface displays the D+ /D- voltage measurement over time in the 0-3.3V range and will automatically adjust the displayed range in real time to account for D+/D- voltage fluctuations.

?

Press the ¡®NEXT¡¯ button to switch to the system parameter setting interface.

Interface 6: System Parameter Setting Interface?

26£ºAuto screen off time

27£ºScreen brightness

28£ºTemperature display C /F

29£ºTheme background color?

30£ºTheme foreground color

Press and hold the "Next" button

to enter into setting state, press ¡°NEXT¡± button to step through the options of auto screen off time, brightness level, temperature display units, theme background color and theme foreground color. Stop on the value you wish to change then press the "PREV" button to change the setting.?

For auto screen off time setting press ¡®PREV¡¯ to repeatedly step though the 10 options from 0 to 9 minutes. Default time is 1 minutes.?

?For the screen brightness setting, press ¡®PREV¡¯ to repeatedly step though the 6 options from 0 to 5 where 0 is the lowest brightness level and 5 is the highest. Default brightness is 4.?

For the temperature display units, pressing the ¡®Next¡¯ button toggles the setting between C and F. default temperature unite is C.?

For theme background color, press ¡®PREV¡¯ to repeatedly step though the 7 options from 0 to 6 where the color sequence is red, green, blue, yellow, light blue, pink, white and black. Default color is 2, blue.?

For theme foreground color, press ¡®PREV¡¯ to repeatedly step though the 7 options from 0 to 6

where the color sequence is red, green, blue, yellow, light blue, pink, white and black. Default ?color is 6, white.

?At any setting state, press and hold the ¡®Next¡¯ button to exit the settings menu.