Overview:
1.Thermocouples are very sensitive, requiring a good amplifier with a cold-compensation reference.
2.This protuct does everything for you, and can be easily interfaced with any microcontroller,
even one without an analog input.
3.Comes with a 2 pin terminal block (for connecting to the thermocouple) and pin header (to plug into any
breadboard or perfboard).

Specification:
1. measurement temperature range: minus 200 degrees Celsius to 1350 degrees Celsius above zero
2. SPI interfaces, high-speed transmission
3. the input voltage is 3-5v DC
4. direct digital output temperature value, no amplifiers, no ADC
5. 14-bit resolution, 0.25 degree temperature accuracy

Note:
1.Works with any K type thermocouple
2 K thermocouples have about ¡À2¡ãC to ¡À6¡ãC accuracy
4.Internal temperature reading
5.3 to 5v power supply and logic level compliant!
6.SPI data output requires any 3 digital I/O pins.

The MAX31855 GND and T- cannot be connected because there is a control switch inside.

Packing Included:
1 x MAX31855 K Type Thermocouple Breakout Board

trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancyservice@diytech.cc

Overview:
1.Thermocouples are very sensitive, requiring a good amplifier with a cold-compensation reference.
2.This protuct does everything for you, and can be easily interfaced with any microcontroller,
even one without an analog input.
3.Comes with a 2 pin terminal block (for connecting to the thermocouple) and pin header (to plug into any
breadboard or perfboard).

Specification:
1. measurement temperature range: minus 200 degrees Celsius to 1350 degrees Celsius above zero
2. SPI interfaces, high-speed transmission
3. the input voltage is 3-5v DC
4. direct digital output temperature value, no amplifiers, no ADC
5. 14-bit resolution, 0.25 degree temperature accuracy

Note:
1.Works with any K type thermocouple
2 K thermocouples have about ¡À2¡ãC to ¡À6¡ãC accuracy
4.Internal temperature reading
5.3 to 5v power supply and logic level compliant!
6.SPI data output requires any 3 digital I/O pins.

The MAX31855 GND and T- cannot be connected because there is a control switch inside.

Packing Included:
1 x MAX31855 K Type Thermocouple Breakout Board